1. Primary Coated Fiber
    Silica, acrylate
  2. Loose Tube
    PBT
  3. Central Strength Member
    Fiber reinforced plastic
  4. Filling Compound
    Thixotropic gel
  5. Filling Compound
    Thixotropic gel
  6. Wrapping Tape
  7. Inner Sheath
    Polyethylene (PE)
  8. Armouring
    Corrugated Steel Tape
  9. Outer Sheath
    Polyethylene (PE)
 

   


DIRECT BURIAL INSTALLATION | DB SERIES

Concentric core design, loose fiber, 2-144 fibers, loose tube, corrugated steel tape armouring
This is a light armoured concentric cable design for direct burial installation. The corrugated steel tape armouring provides good protection against rodents yet allows the cable to retain outstanding flexibility for easy installation.

It can be supplied with 2 to 144 fibers; either single-mode, multimode or both.
Water blocking filling compound prevents water penetration along the cable.
 
TECHNICAL DATA
Temperature range*
operation
storage
installation
-30 to 70°C
-40 to 70°C
-10 to 55°C
Bending radius*
temporary unloaded
permanently (one turn) and during installation
10 x cable diameter
15 x cable diameter
Tensile force*
during installation
permanent
2.7kN
1.5kN
Crush resistance*
  3.5kN
Water penetration
complies with IEC 60794-1-2-F5
Delivery information
cable weight
supplied lengths
drum type
270kg/km - 380kg/km
2km - 6km
W16 - W22
* Tested in accordance with IEC 60794-1-2
For more product information, please call +60.3.5519.5699 or email us at marketing@opcom.com.my